
Living room and open kitchen
Large windows load the room all afternoon. An indoor unit on the right wall keeps the temperature even without a draught over the seating.
We look at the room, size the system to it and install it cleanly. It is handed over commissioned and tested.

On the top floor the heat sits there until midnight, in a south facing office concentration drops off after two, and in the bedroom an open window brings noise instead of cool air. A split system takes the heat out of the room instead of moving it around.
Because the outdoor unit does the work, all that stays inside is a slim casing on the wall. No hose in the window gap, no wheeled unit in the middle of the room, no balcony door left open on a summer night.
In short
From the first assessment to servicing: these points come up with every split system. You can raise your questions about them in your enquiry.
Room size, glazing and how the room is used decide which class of unit fits. The largest is rarely the right one.
One outdoor unit for one indoor unit, or one outdoor unit for several rooms. What fits depends on the layout of the home.
Wall penetration, refrigerant lines, condensate routing and mounting are part of it, laid out cleanly and sealed properly.
Before first use come a leak test, evacuation, charging and a test run in which the controls are explained.
Filters, heat exchanger and the condensate path need regular checks so the system stays quiet and economical.
Every room sets a different task. That decides which unit goes on which wall.

Large windows load the room all afternoon. An indoor unit on the right wall keeps the temperature even without a draught over the seating.

Computers, lighting and people heat the room through the day. Separately controlled indoor units hold each room at its own setting.

At night what counts is not hearing the unit at all. That decides the class of unit, and the unit sits so the air does not fall onto the bed.
The figure in the brochure applies to the unit on a test rig. In a real room what matters is how the air runs: too little clearance to the ceiling and the unit roars against the surface. Mounted too low and the stream falls on the back of people’s necks.
With the indoor unit set correctly, the cool air runs into the room high up, mixes, and only then sinks. The condensate line needs a fall along its whole length so nothing stands and nothing gurgles. That is the difference between a system that annoys and one you never think about.
Air leaves the unit, runs into the room high up, mixes and then sinks.
Photographs showing the build of the units and typical installation situations in living rooms and offices.
Our base is in Gangelt, in the district of Heinsberg. This page is for Heinsberg and its villages, for homes as much as for offices and practices.
A few sentences are enough. We will get in touch, agree a time and look at it with you before anything is ordered.
Jansen GmbH Gebäudetechnik. Managing director Lennard Jansen, Elektrotechnikermeister (erworben in Deutschland).
The things people ask most often on the phone, answered here.
It depends on the size of the room, on how many indoor units there are and on how far the lines have to run. A reliable price can therefore only be given after a look on site.
Yes. Split units work as a heat pump and heat the room in the shoulder season. Whether that pays off depends on the building and on the heating already in place.
Indoor units are very quiet on the lower fan settings. More important than the catalogue figure is the installation: the right wall, enough clearance to the ceiling and a condensate line that falls along its whole length.
On the building: the wall build up, the route for the lines and the way to the consumer unit. That can be settled at a site visit, before you sign anything.
Yes. Filters and the heat exchanger clog up over time, and the condensate path has to stay clear. It is best to mention servicing in your enquiry.
Jansen GmbH Gebäudetechnik
Geilenkirchener Straße 65 a, 52538 Gangelt, Deutschland
Lennard Jansen
Phone: +49 2454 938644
Fax: +49 2454 938645
Email: info@jansen-elektro.de
Registered at Amtsgericht Aachen, HRB 9411 und HRB 9946.
VAT identification number under section 27 a of the German VAT Act: DE404851628
Professional title of the managing director: Elektrotechnikermeister (erworben in Deutschland). Competent chamber and supervisory authority: Handwerkskammer Aachen, Sandkaulbach 17-21, 52062 Aachen. The German Trade and Crafts Code and the rules of that chamber apply and can be inspected there.
The European Commission provides a platform for online dispute resolution. We are neither obliged nor willing to take part in dispute resolution proceedings before a consumer arbitration body.
The content of this site was prepared with care. We give no warranty for its accuracy, completeness or currency. The operators of external sites we link to are responsible for their content. At the time the links were set, no legal infringements were apparent.
The texts, design and graphics on this site are protected by German copyright law. Any use beyond the limits of copyright law requires our consent.
The photographs on this site come from the Pexels picture library. They show units and rooms by way of illustration and no installation belonging to this company. The company mark belongs to Jansen GmbH Gebäudetechnik.
Jansen GmbH Gebäudetechnik
Geilenkirchener Straße 65 a, 52538 Gangelt, Deutschland
+49 2454 938644
info@jansen-elektro.de
This site consists of fixed files. It contains no advertising networks, no analytics services, no social buttons and no embedded content from third parties.
When the page is requested, your browser transmits the usual connection data to the server, including the shortened address of your connection, the date and time and the file requested. This data serves the operation and the security of the site. The legal basis is Article 6 paragraph 1 point f of the General Data Protection Regulation.
What you write into the form is transmitted in encrypted form to the enquiry system we work with and stored there until your enquiry has been dealt with. We use these details only to reply to you. The legal basis is Article 6 paragraph 1 points b and f of the General Data Protection Regulation. We need a phone number and a message in order to be able to reply at all. The email address is voluntary.
This site sets a single cookie named site_lang. It contains only the language you have chosen, that is de, en, pl or ru, applies to the whole site, expires after twelve months and is set with SameSite equal to Lax. If you have chosen a language other than German, the start page opens in that language on your next visit. The cookie is necessary for operation under section 25 paragraph 2 number 2 TDDDG and therefore needs no consent. When you close the cookie notice, your browser additionally stores an entry in its local storage so that the notice does not appear again. You can delete both at any time in your browser settings.
You may request information about the data stored about you, as well as its correction, deletion or restriction, and you may object to processing. Please write to the address given above. You may also lodge a complaint with a data protection supervisory authority. The competent one is the State Commissioner for Data Protection and Freedom of Information of North Rhine Westphalia.
This site sets exactly one cookie and additionally uses your browser local storage for a single note.
Nothing else. No analytics, no advertising, no tracking pixels, no third party services. You can delete both in your browser settings.